Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Medical Operating Theatre Pendant, Pendant, Fashion Jewelry manufacturer / supplier in China, offering High Quality in Economical Price! ! Medical Gas Pendant (THR-MP580), Hospital Rise-and-Fall Transport Stretcher Cart (THR-5B), Luxurious Five Function Electric ICU Bed (THR-EB5201) and so on.

1
    YRS
General Supplier
Supplier Homepage Furniture Outdoor Furniture THR-VT1800 Hospital Patient Ventilator Medical Device

THR-VT1800 Hospital Patient Ventilator Medical Device

Get Latest Price
Min. Order / Reference FOB Price
1 Unit US $8500.00/ Unit
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Brand: THR
Place of Origin: Jiangsu, China
Instrument classification: Class II
Warranty: 1 year

THR-VT1800 Hospital Patient Ventilator Medical Device

Product Dimension

ALL MANIN UNIT HAS PASS THE CE

The automatic conversion for standby power while AC power outage, keep working not less than 1 hour

Component Details

Display: LED Display Following Parameters Operating mode and respiratory rate;

——Ventilator control frequency set by medical staff;

——Tidal volume of each breath in the patient; ——Occurrence of spontaneous breath in the patient and spontaneous breathing frequency; ——Expiratory phase and inspiratory phase and actual respiratory rate;

——Minute volume;

——Setting and adjustment of inspiration triggering pressure, PEEP, and highest airway pressure;

——Real-time variation in internal airway pressure.

Ventilator Construction:

--Environmental Protection Material construction, hardly to be broken.

-- Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions

TECHNIQUES SPECIFICATIONS

Physical specifications

DisplayLED DisplayMode:pneumatically powered and electrically controlled systemTrolley: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisionsTechnical Specifications:Gas requirement: Medical oxygen with a pressure ranging from 280~600kpasafety valve <12.5 kPaRespiratory Rate6~60 times/ minOxygen concentration output<50%minute volume≥18L modes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUALPEEP:0.1 ~ 1.0 kPaPtr: -4 ~ 10 hPaIMV frequency:1~12 bpmI/E Ratio:1:1.5; 1:2.0; 1:2.5; 1:3.0Tidal Volume0-1500mlInspiratory Plateau:0~1sMaximum Safety Pressure≤ 6.0kPaSigh: one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting pointPressure limit range:0 ~ 6.0 kPaAirway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.9 kPa ~ 5.4 kPa;Upper: 0.5 kPa±0.2 kPaVentilation Volume alarm: ≥ 18L/ MIN Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120sThe airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.Operating conditionsAmbient temperature: 10 ~ 40oCRelative humidity:no higher than 80 %Atmospheric pressure:860 hPa ~ 1060 hPaPower requirement: 100-120 Vac, 50/60 Hz; Attention: the AC power supply used for the anesthesia machine must be wellgrounded.Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. StorageAmbient temperature: -15oC ~ +50oCRelative humidity: no higher than 95 %Atmospheric pressure: 86 kPa ~ 106 kPa. It should be stored in a room without corrosive gas and well ventilatedPackagepackaging boxcomply with the requirement of GB/T 15464 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation Moisture protection and rain protection to ensure that product is protected from natural damage. Safty & AlarmGas source pressureImmediate alarm; “high level alarm” indicator flickers raising an audible alarm.Airway Pressure AlarmThe airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm. Tidal Volume AlarmLower than 50ml, The alarm will be raised after one breathing cycle. Ventilation Volume AlarmLower: 0~12L/Min;Up: 18L/ MinBattery Voltage AlarmIt alrms when the battery voltage is lower than 10.5V.Power On Self TestSelf test before working, assure it's working normally.

Company information

FAQ